The Most Difficult Install Ever, Eretrea Greece

August 3, 2022 By admin

The city of Eretrea in Greece, one of the best known Archaeological sites in the world, has had a much needed upgrade. A Flovac vacuum system has been installed to replace old septic tanks that still serviced the houses in the town.

Two vacuum pump stations were required, as well as 414 collection pits, a cable monitoring system and 28,000 meters of pipework including the house connections.  A vacuum system was chosen due to the difficult ground conditions and the flexibility that the pipework allowed for. A gravity pipe system would require deep trenching and straight lengths of pipe.  Vacuum mains can be installed with full flexibility and can be rerouted around difficult areas.

 

Difficult Installation

The city was an important city in Ancient Greece beginning at the time of the Bronze Age in the 8th century BC and was a seat of trade,  commerce and education. As the site is still under archaeological excavation it is still common to find artifacts while digging into the ground. We often found evidence of graves, walls, bronze artifacts and perfume bottles. Some more than 2,000 years old. At all times during excavation we were accompanied by two archaeologists and no excavation could take place without them. Once something was found, we would have to stop pipelaying and wait until drawings were done. Permission would then needed be granted from the Central Archaeological Institute to continue, which often took a long time.

We also needed to deal with a water table at 60-70 cm (24 inches). You would think that this close to the sea that it would be salt water but no, it was clear sweet fresh water. At 90 cm (36 inches) there is a hard crust which when perforated allowed salt water to ingress.

A very difficult but a very rewarding project

Eretrea

Filed Under: Projects, Septic to Sewer Replacement Program Tagged With: Greece, Septic to Sewer Replacement

You Tube Video Library

How Vacuum Sewers Work

Flovac Valve Blockage Test

Vacuum Main Leak Test

Vacuum Valve Easy Access

 

Recent Posts

  • How to identify 5,000,000 litres per year of salt water entering your sewer network at a single glance
  • Key Largo using monitoring for hurricane preparedness
  • The Most Difficult Install Ever, Eretrea Greece
  • Gran Marina del Estrecho, a new marina for megayachts
  • New Vacuum Sewer Project in Portugal

Follow Us!